How to make agar plates at home: recipes, pressure cooking and pouring
Mix agar and light malt extract into water, pressure-cook it at 15 PSI, cool it to about 50°C and pour it into dishes in still air. This guide compares MEA and PDA recipes, cooker times and safety, condensation, storage, plastic and glass dishes, and plates that won't set or all go moldy.

Derick14 min read

To make agar plates, dissolve about 20 g of agar powder and 20 g of light malt extract per litre of water, pressure-cook it in jars at 15 PSI for 30 to 45 minutes, let it cool to about 50°C (122°F), then pour a thin layer into each dish in a still air box or in front of a flow hood. That's GroCycle's light malt extract agar, doubled from its 500 mL batch (GroCycle); the cooking time runs from GroCycle's 30 minutes to a SARE-hosted lab guide's 45 (SARE). Let the plates set for up to an hour, store them upside down, and use them within a few weeks. Our photos show our own lab bench, media and plates, not a side-by-side test of recipes.
Sources: GroCycle, UF/IFAS Extension, Penn State's mushroom culture guide, a lab guide hosted by USDA SARE, Adelaide University, the FDA, a University of Alaska Fairbanks autoclave procedure, Presto's pressure cooker manual, Thermo Fisher, Rootlab, Mediamatic, North Spore's help center and an agar gel study, checked 22 November 2026.
What are agar plates used for in mushroom growing?
Agar plates give mycelium a clean, see-through surface, so you can tell your culture from anything else that grows. Growers use them to clean up a contaminated culture, clone a mushroom, germinate spores and test liquid culture before it goes on grain. GroCycle says malt extract agar "is ideal for cloning mushrooms and creating mushroom cultures", and potato dextrose agar is "especially useful in spore germination and maintaining mother cultures" (GroCycle).
This post covers making the plates. For the jobs themselves, see our agar page, cloning a store-bought mushroom and testing liquid culture on agar; for judging what grows, what mycelium looks like on agar and mold or mycelium?
What's the best agar recipe for mushrooms?
Light malt extract agar (often called MEA or LMEA) is the simplest to start with: agar, light malt extract and water. Potato dextrose agar (PDA) is the other common choice. Sources agree on 15 to 20 g of agar per litre and differ more on the food. Per litre of water:
| Recipe | Agar | Food | Extras | Source |
|---|---|---|---|---|
| Light malt extract agar | 20 g | 20 g light malt extract | "Some growers add 1 g of yeast" per 500 mL | GroCycle |
| Malt extract agar, lab | 20 g | 20 g malt extract | pH adjusted to 6.5 | Adelaide University |
| Malt extract agar, lab, for yeasts and molds | 20 g | 20 g malt extract, 20 g glucose | 1 g peptone | FDA |
| Potato dextrose agar | 20 g | 20 g dextrose, 4 g potato infusion | "Growers often add yeast" | GroCycle |
| Potato dextrose agar, oyster | 15 g | 20 g glucose or table sugar, broth from 200 g of potato | None | UF/IFAS |
| Potato dextrose yeast extract agar, button mushroom | 15 g | 10 g dextrose, broth from 250 g of potatoes | 1.5 g yeast extract | Penn State |
| Premixed enriched malt extract agar | 50 g of the mix | In the mix | Bought "anti-biotic free" | SARE |
GroCycle's and SARE's amounts are for 500 mL; we doubled them. SARE's 50 g is the whole premix, agar and malt together.
Light malt or dextrose? Malt extract is the food in MEA; dextrose (a plain sugar) plus potato is the food in PDA. Some lab malt recipes add both, as the FDA's does. GroCycle calls malt "very effective for growing saprotrophic mushroom species", the ones that feed on dead wood and plants, which covers most gourmet species (GroCycle). We found no source that tested light against dark malt extract for mushroom cultures; recipes just call for light.
Peptone and yeast are optional extras: 1 to 1.5 g per litre in the lab recipes (FDA, Penn State), 2 g in GroCycle's. Start without them (our advice); GroCycle agrees: "When you first begin, it's best not to use complicated agar recipes."
Antibiotics slow bacteria, not mold. Rootlab, which sells antibacterial malt agar plates, says they "will not prevent non-bacterial contaminants such as mould or other competing fungi" (Rootlab), and the SARE guide recommends its agar "anti-biotic free" (SARE). We found no home-grower source we'd trust for a dose, so we don't give one.
How do you mix and sterilize agar?
Weigh, dissolve, fill jars two-thirds, then pressure-cook at 15 PSI, timing from when the cooker reaches pressure. Agar feeds anything that lands on it, so it needs sterilizing, not just boiling; the SARE guide lists "Agar, grain, and sawdust" among what it pressure-cooks at 15 PSI (SARE).
- Weigh the agar and malt on a digital scale.
- Dissolve them in hot water. GroCycle stirs "vigorously until the agar and malt extract are dissolved" (GroCycle); Penn State boils its broth and adds the agar with "stir until dissolved (watch carefully or it will boil over)" (Penn State).
- Fill jars or bottles about two-thirds, "to prevent them from boiling over during sterilization" (GroCycle). Close them with a lid that lets steam in and out: GroCycle uses lids with holes stuffed with polyfill, and SARE covers the cap with tin foil (SARE).
- Pressure-cook at 15 PSI. At that pressure near sea level a cooker reaches about 121°C (250°F) (our grain spawn guide). Start timing at pressure: "only start timing once the pressure cooker reaches 15 PSI" (GroCycle).
- Let it cool in the cooker until the pressure is gone (see the safety list below).

How long? It depends on the volume and on the vessel, and sources range from 10 to 45 minutes:
| Batch | Time | Equipment | Source |
|---|---|---|---|
| 500 mL in jars | 30 min at 15 PSI | Pressure cooker | GroCycle |
| 500 mL in one 750 mL bottle | 45 min at 15 PSI | Pressure cooker | SARE |
| 1 litre | 30 min at 15 psi | Autoclave or pressure cooker | UF/IFAS |
| About 500 mL | 20 min once "the pressure is high" | Pressure cooker | Mediamatic |
| 1 litre | 15 min at 121°C | Autoclave | Penn State |
| 1 litre | 10 min at 121°C | Autoclave | Adelaide University |
Big volumes take longer to heat through. A University of Alaska Fairbanks autoclave procedure says "Large volumes of liquid (>500 mL) will NOT reach 121C as quickly as smaller volumes" and that the whole volume has to sit at 121°C for 15 minutes (UAF). The short times are for lab autoclaves; in a stovetop cooker, use 30 minutes for jars of under 500 mL and 45 for a single bottle of 500 mL or more, as SARE does (our reading of the table). Above 2,000 feet, add time as in our altitude rule for grain.
How do you use a pressure cooker safely for agar?
Check the cooker before you start, stay with it, and never open it under pressure. Presto's manual says to "Always check the vent pipe before use" and warns, "Any pressure in the cooker can be hazardous" (Presto).
- Loose lids, two-thirds full, real canning jars. "Keep lids and caps loosely closed. Tightly sealed containers may explode," and "Do not use old food jars" in an autoclave, because "they will break" (UAF). That lab uses only borosilicate glass or autoclavable plastic; at home, canning jars made for pressure canning or heat-rated lab bottles are the usual choice (our reading).
- Stay close. The SARE guide says to "Stay within earshot of pressure cooker to ensure the pressure regulator is rattling" and "Do not let rise above 15 PSI" (SARE).
- Let it cool on its own. "Do not open when there is positive pressure inside; otherwise, the media may boil over" (UF/IFAS). If the lid won't open easily, "do not force it open" (Presto).
- Move hot jars gently. Hot liquids "can be superheated and boil violently if jostled" (UAF). Use heat-resistant gloves.
- Flame tools away from the alcohol. If you heat a scalpel, do it outside the still air box: why.
How do you pour agar plates?
Wait until the agar is warm but still runny, then pour a thin layer into each dish in still air, opening each one as briefly as you can.
- Cool it to 46–52°C (115–125°F). At that point it's "cool enough to handle but still warm enough to remain liquid" and it "usually takes a couple of hours" (GroCycle); UF/IFAS says about 50°C (122°F) (UF/IFAS). Pour too hot and it "may warp or damage plastic Petri dishes" (GroCycle). An infrared thermometer on the jar's side is a quick check (our advice).
- Set up clean air. GroCycle says to work "in front of a laminar flow hood, but a still air box will also help reduce contamination" (GroCycle). See our still air box page, the flow hood entry and where to do culture work.
- Wipe and stack. The SARE guide wipes the dish sleeve and hands with alcohol, then stacks the dishes "right side up - the larger lids should be on top of the smaller bases" (SARE).
- Pour from the bottom up. "Pour from the bottom of the stack to the top, keeping each plate open for as little time as possible" (SARE). Pour "enough to cover the bottom" (GroCycle). SARE gets 15 to 20 plates from 500 mL, about 25 to 33 mL each (our arithmetic).
- Let them set. GroCycle allows "around 30 minutes to 1 hour" to cool and solidify; SARE leaves the hood running and lets plates cool "for up to an hour before using or wrapping with parafilm for storage".
Sealing, labelling and keeping plates clean while you work are covered in how to keep agar plates clean. Label the bottom, not the lid (why).
Is condensation on agar plates normal?
A little, right after pouring, yes: "This initial condensation will dissipate and is usually not a problem" (GroCycle). Heavy or lasting condensation means the plates were warm while their lids were cooler, and water moved from the agar onto the lid (our reading). North Spore's help center puts it this way: "Condensation in the plates means there is a heat source driving out water from the agar, which will dry it out quickly" (North Spore help center). Drops that fall back onto the agar can carry contamination across the plate, so keep them on the lid (our reading).
To keep it down:
- Pour cooler, at the 46–52°C above (our advice, since a hotter pour gives off more steam).
- Let plates cool fully before you store them. That "will prevent moisture from evaporating and condensing on the lids during storage" (Thermo Fisher).
- Store them upside down (next section).
- Warm cold plates before opening. GroCycle lets them come to room temperature first: "This helps to prevent condensation that may cause contamination" (GroCycle).

How do you store agar plates, and how long do they keep?
Upside down (agar on top), sealed, and used within a few weeks. Sources split on the fridge:
| Source | Where | How long |
|---|---|---|
| GroCycle | "a sealed container or plastic bag in the refrigerator at 35 to 40°F (2 to 4°C)" | "use them within two to four weeks" |
| Thermo Fisher, lab plates | Upside down, "at 2°C to 8°C" | Non-selective agars "up to four weeks" |
| North Spore help center, its pre-poured plates | "upside down in the refrigerator", in their original container | No time given |
| Rootlab, its antibacterial plates | "Store your plates at room temperature. Do not refrigerate them until they have been colonised." | "30 to 45 days" |
Upside down keeps drops off the agar: Thermo Fisher stores plates that way "to prevent moisture from condensing out of the agar and onto the plate lids" (Thermo Fisher). Rootlab skips the fridge because cold "can cause condensation to build up inside the dish" (Rootlab). Either works, in our reading, if the plates stay sealed and fridge plates warm up before you open them.
These times are for blank plates. Colonized cultures keep longer: see how long agar cultures keep.
How do you check agar plates before using them?
Look at every plate before you open it. Before use, GroCycle says to "check them carefully for any signs of contamination" (GroCycle), and Thermo Fisher says to "Check each plate you are using for visible signs of deterioration" (Thermo Fisher). A blank plate should stay blank: any spot, film or fuzz on agar you haven't used yet is contamination from the pour or the cook (our reading). Throw that plate out, unopened.
Our advice: leave a new batch at room temperature for a few days before you use it, so anything that got in has time to show.
Plastic or glass petri dishes?
Plastic for most home growers; glass if you'd rather wash and reuse. GroCycle says "Disposable plastic Petri dishes supplied in a pre-sealed, sterilized pack work well" (GroCycle), and they're ready to pour into. Mediamatic's guide names "Glass petri dishes which can be heat sterilized and are reusable" as the alternative (Mediamatic), but they need their own sterilizing before you pour, and they cost more up front (our reading). The one plastic rule is to pour cool enough not to warp it (GroCycle).
UF/IFAS adds a third option: sterilize the medium inside small glass jars, so "the user will avoid the pouring phase" (UF/IFAS).
How do you transfer a wedge to a fresh plate?
Cut a small piece of clean mycelium with a sterile blade and set it on fresh agar, mycelium side down, then close the lid at once (our advice on orientation). When it cuts a plate into cubes to inoculate grain, UF/IFAS says to "Heat, sterilize, and then cool down the blade before cutting the agar culture plate" and to "Cut the fungal mycelium and the agar into small cubes" (UF/IFAS). Penn State's button mushroom guide keeps it small, "The size of the inoculum plug should not exceed 3 x 3 mm", and says the original plug "should not be used for new transfers" (Penn State).
Pick clean, typical growth and skip any sector that looks different; our agar page covers sectors and how many transfers to make from one line. To go from a clean plate to grain, see inoculating grain from agar.

Why didn't my agar set, and why did every plate get contaminated?
Most failures trace back to the recipe, the cook or the air during the pour:
| Problem | Likely cause | Fix |
|---|---|---|
| Agar stayed runny or soft | Too little agar: the recipes above use 15–20 g per litre | Weigh it; don't guess with spoons (our advice) |
| Lumpy, or set only in patches | Powder that didn't dissolve before cooking (our reading) | Stir until no grains are left (GroCycle, Penn State) |
| Weak, soft gel after a long hot wait | Holding agar hot for a long time weakens it: in one study, holding agar at 80°C for hours to days "leads to weaker agar gels" (Mao et al.) | Pour once it's cool enough; don't keep it hot for hours (our advice) |
| Heavy condensation | Poured too hot, stored warm, or opened cold | See the condensation section |
| Warped dishes | Poured too hot (GroCycle) | Cool to 46–52°C first |
| Contamination on every plate | The whole batch points to the cook; see what the pattern means | Time from 15 PSI, give bigger jars longer, and check the cooker reached pressure (our advice) |
| Contamination on a few plates | Spotty contamination points to air or hands during the pour (what the pattern means) | Work in a still air box, open each dish briefly, and pour from the bottom of the stack |
To tell mold from bacteria on a plate, see our contamination ID guide.
How do you track agar batches in Hypha?
Save your agar as a recipe, log each batch you pour, and link plates back to it. In Hypha, tap Prep, then Recipes, then the + button (Add recipe). Enter a Recipe name such as "LME 20/20", set Growth Stage & Container to Culture and Agar Plate, add your agar and malt with Add input, and use Set expected output for how many plates a batch makes (say, 20). Write your cooker time and pour temperature in the instructions box, then tap Create.
Each time you pour, open the recipe, tap Prep this recipe, correct Actual outputs per batch if fewer plates came out, add Notes such as "45 min at 15 PSI, poured at 50°C, 3 plates with heavy condensation", and tap Confirm prep. The plates go into your Inventory, and the recipe's Prep history lists every batch. When you put a culture on a plate, add it under Grows → Blocks → + → New (or Transfer, from its parent), choose stage Culture and container Agar Plate, and pick the batch's recipe under Recipe. If a plate grows mold, Finish it as Failed and check Add contaminated flag, so the plate is tagged as contaminated, not just failed. More on following a culture line in our grow log guide.
Hypha doesn't time your cooker, read its pressure or tell you whether a plate is clean. Download Hypha; the free plan holds 25 active blocks, and each plate counts until you archive it.